    GK600 Series General Purpose Frequency Changer (VFD)

    GK600 Series General Purpose Frequency Changer (VFD), adopting advanced sensorless vector control technology with robust sensorless vector control, precise sensorless vector control, and different V/f curves programmable, are widely applied to various industrial sectors. GK600 series Frequency Changer (VFD) are competitive in market with comprehensive advantages, such as its widely-used characteristics, favorable performance-price ratio, and easier operation and maintenance for users, etc.

    1.Model Explanation

    2.Nameplate Information

    3.Information of Product Model

    Table 2 Product model and technical data

    Variable Frequency Drive model

    Power rating (kW)

    Rated output current (A)

    Rated input current (A)

    Applicable motor (kW)

    Brake unit

    GK600-4T2.2G/3.7LB

    2.2G

    2.2

    5.5

    9.2

    2.2

    Built-in

    3.7L

    3.7

    9

    14.9

    3.7

    GK600-4T3.7G/5.5LB

    3.7G

    3.7

    9

    14.9

    3.7

    5.5L

    5.5

    13

    21.5

    5.5

    GK600-4T5.5G/7.5LB

    5.5G

    5.5

    13

    21.5

    5.5

    7.5L

    7.5

    17

    27.9

    7.5

    GK600-4T7.5G/11LB

    7.5G

    7.5

    17

    27.9

    7.5

    11L

    11

    24

    39

    11

    GK600-4T11G/15LB

    11G

    11

    24

    39

    11

    15L

    15

    30

    50.3

    15

    GK600-4T15G/18.5LB

    15G

    15

    30

    50.3

    15

    18.5L

    18.5

    39

    60

    18.5

    GK600-4T18.5G/22L(B)*

    18.5G

    18.5

    39

    60

    18.5

    Built-in optional

    22L

    22

    45

    69.3

    22

    GK600-4T22G/30L(B)*

    22G

    22

    45

    69.3

    22

    30L

    30

    60

    86

    30

    GK600-4T30G/37L(B)*

    30G

    30

    60

    86

    30

    37L

    37

    75

    104

    37

    GK600-4T37G/45L(B)*

    37G

    37

    75

    104

    37

    45L

    45

    91

    124

    45

    GK600-4T45G/55L(B)*

    45G

    45

    91

    124

    45

    55L

    55

    112

    150

    55

    GK600-4T55G/75L

    55G

    55

    112

    150

    55

    Externally mounted when needed

    75L

    75

    150

    201

    75

    GK600-4T75G/90L

    75G

    75

    150

    201

    75

    90L

    90

    176

    236

    90

    GK600-4T90G/110L

    90G

    90

    176

    160**

    90

    Externally mounted when needed

    110L

    110

    210

    192**

    110

    GK600-4T110G/132L

    110G

    110

    210

    192**

    110

    132L

    132

    253

    232**

    132

    GK600-4T132G/160L

    132G

    132

    253

    232**

    132

    160L

    160

    310

    285**

    160

    GK600-4T160G/185L

    160G

    160

    310

    285**

    160

    185L

    185

    350

    326**

    185

    GK600-4T185G/200L

    185G

    185

    350

    326**

    185

    200L

    200

    380

    354**

    200

    GK600-4T200G/220L

    200G

    200

    380

    354**

    200

    220L

    220

    430

    403**

    220

    GK600-4T220G/250L

    220G

    220

    430

    403**

    220

    250L

    250

    470

    441**

    250

    GK600-4T250G/280L

    250G

    250

    470

    441**

    250

    280L

    280

    520

    489**

    280

    GK600-4T280G/315L

    280G

    280

    520

    489**

    280

    315L

    315

    590

    571**

    315

    GK600-4T315G/355L

    315G

    315

    590

    571**

    315

    355L

    355

    650

    624**

    355

    GK600-4T355G/400L

    355G

    355

    650

    624**

    355

    400L

    400

    725

    699**

    400

    GK600-4T400G/450L

    400G

    400

    725

    699**

    400

    450L

    450

    820

    790**

    450

    * means brake unit is optional built-in. Take 18.5G/22L for example: the model without brake unit is GK600-4T18.5G/22L, and the model with brake unit is GK600-4T18.5G/22LB. Braking resistor needs to be mounted externally with reference to Table 3-3.

    ** means the rated input current configured a DC reactor. The drive GK600-4T90G/110L or above is provided with an external-mounted DC reactor in shipment as default. Be sure to connect the DC reactor. Failure to comply may result in drive abnormal running.

    4.Technical Features of GK600 Frequency Changer (VFD)

    Table 3 Technical Features of GK600 Frequency Changer (VFD)

    Power input

    Rated input voltage

    3-phase AC208V/220V/230V/240V/380V/400V/415V/440V/460V/480V

    1-phase AC220V/AC230V/AC240V

    Rated input current

    See Section 2.3 in the User Manual

    Frequency

    50Hz/60Hz, tolerance ±5%

    Allowable range of voltage

    Continuous voltage fluctuation ±10%, short fluctuation -15%~+10%, i.e. 323V~528V;

    Voltage out-of-balance rate<3%, distortion rate as per the requirements of IEC61800-2

    Power output

    Standard applicable motor (kW)

    See Section 2.3 in the User Manual

    Rated current (A)

    See Section 2.3 in the User Manual

    Output voltage (V)

    3-phase: 0~ rated input voltage, error < ±3%

    Output frequency (Hz)

    0.00~ 600.00Hz; unit: 0.01Hz

    Overload capacity

    150% - 1min; 180% - 10s; 200% - 0.5s

    Control characteristics

    V/f patterns

    V/f control

    Sensor-less vector control 1

    Sensor-less vector control 2

    Range of speed regulation

    1:100 ( V/f control, sensor-less vector control 1)

    1:200 (sensor-less vector control 2)

    Speed accuracy

    ±0.5% (V/f control)

    ±0.2% (sensor-less vector control 1 & 2)

    Speed fluctuation

    ±0.3% (sensor-less vector control 1 & 2)

    Torque response

    < 10ms (sensor-less vector control 1 & 2)

    Starting torque

    0.5Hz: 180% (V/f control, sensor-less vector control 1)

    0.25Hz: 180% (sensor-less vector control 2)

    Basic functions

    Start frequency

    0.00~ 600.00Hz

    Accel/Decel time

    0.00~60000s

    Carrier frequency

    0.7kHz~16kHz

    Frequency setting sources

    Digital setting + keypad ?/?

    Digital setting + terminal UP/DOWN

    Communication

    Analog setting (AI1/AI2/EAI)

    Terminal pulse setting

    Motor started methods

    Started from starting frequency

    DC braking and then started

    Speed search started

    Motor stopped methods

    Ramp to stop

    Coast to stop

    Ramp stop + DC brake

    Basic functions

    Dynamic braking capacity

    Brake unit action voltage: 650V~750V; service time: 0.0~100.0s; brake units for GK600-4T45G/55L and below are built in or can be built in. See table 2-1

    DC braking capacity

    DC braking start frequency: 0.00~600.00Hz

    DC braking current: 0.0~100.0%

    DC braking time: 0.0~30.00s

    Input terminals

    6 digital inputs, one of which can be used for high-speed pulse input. Compatible with active open collectors NPN, PNP and dry contact input. Digital inputs can be extended to 7

    2 analog inputs, one of which is voltage/current programmable, and the other supports voltage only. Analog inputs can be extended to 3, and the extended one is voltage/current programmable

    Output terminals

    1 high-speed pulse output, 0~50kHz square wave signal output; can output signals such as command frequency, or output frequency, etc.

    1 digital output

    1 relay output (can be extended to 2)

    1 analog output (can be extended to 2), voltage/current output programmable; can output signals such as setting frequency, or output frequency, etc

    Featured functions

    Parameter copy, parameter backup, common DC bus, free switchover between two motors’  parameters, flexible parameter displayed & hidden, various master & auxiliary command and switchover, speed search started, a variety of Accel/Decel curves optional, automatic correction of analog, contracting brake control, 16-step speed control programmable (2-step speed supports flexible frequency command), wobble frequency control, fixed length control, count function, three faults recorded, over excitation brake, over voltage stall protection, under voltage stall protection, restart upon power loss, skip frequency, frequency binding, four kinds of Accel/Decel time, motor thermal protection, flexible fan control, process PID control, simple PLC, multi-functional key programmable, droop control, parameter identification, field-weakening control, high-precision torque restraint, V/f separated control

    Protection functions

    Refer to Chapter 7- Troubleshooting in the User Manual

    Environment

    Place of operation

    Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drop or salt, etc.

    Altitude

    0~2000m

    De-rate 1% for every 100m when the altitude is above 1000 meters

    Ambient temperature

    -10? ~50?

    Relative humidity

    0~95%, no condensation

    Vibration

    Less than 5.9m/s2 (0.6g)

    Storage temperature

    -40? ~+70?

    Others

    Efficiency at rated Amps

    Rated power

    7.5kW and below: =93%

    11~ 45kW: = 95%      55kW and above: =98%

    Installation

    Wall-mounted

    IP grade

    IP20

    Cooling method

    Fan cooled

    Control Board Diagram

    Wiring Diagram

    Control Terminal Specification

    Control terminal specification

    Category

    Terminal

    Terminal designation

    Specification

    Analog input

    +10V

    Analog input

    reference voltage

    10.3V ±3%

    Maximum output current 25mA

    The resistance of external potentiometer should be larger than 400O

    GND

    Analog ground

    Isolated from COM interiorly

    AI1

    Analog input 1

    0~20mA: input impedance - 500O, maximum input current - 25mA

    0~10V: input impedance - 100kO, maximum input voltage - 12.5V

    Switch S2 on control board for jumping from 0~20mA and 0~10V, factory default: 0~10V

    AI2

    Analog input 2

    -10V~10V: input impedance - 25kO

    Range: -12.5V~+ 12.5V

    Analog output

    AO1

    Analog output 1

    0~20mA: impedance - 200O~500O

    0~10V: impedance = 10k

    Switch S3 on control board for jumping between 0~20mA and 0~10V, factory default: 0~10V

    GND

    Analog ground

    Isolated from COM interiorly

    Digital input

    +24V

    +24V

    24V±10%, Isolated from GND interiorly

    Maximum load - 200mA

    PLC

    Digital input

    Common terminal

    Used for switching between high and low levels, short-circuited with +24V when delivery, i.e. low value of digital input valid

    External power input

    COM

    +24V ground

    Isolated from GND interiorly

    X1~X5

    Digital input

    Terminals 1~5

    Input: 24VDC, 5mA

    Range of frequency: 0~200Hz

    Range of voltage: 10V~30V

    X6/DI

    Digital input/pulse input

    Digital input: same as X1~X5

    Pulse input: 0.1Hz~50kHz; range of voltage: 10-30V

    Digital output

    Y1

    Open collector output

    Range of voltage: 0~24V

    Range of current: 0~50mA

    Y2/DO

    Open collector out / Pulse out

    Open collector output: same as Y1

    Pulse output: 0~50kHz;

    Relay output

    RA/RB/RC

    Control board relay output

    RA-RB: NC; RA-RC: NO

    Contact capacity: 250VAC/3A, 30VDC/3A

    Terminal 485

    Interface

    485+

    485 differential signal +

    Rate: 4800/9600/19200/38400/57600/115200bps

    485-

    485 differential signal -

    Maximum distance - 500m (standard network cable used)

    GND

    485 communication shield grounding

    Isolated from COM interiorly

    Keypad 485 interface

    CN4

    Keypad 485 interface

    Maximum communication distance is 15m when connected to Keypad

    Use standard network cable

    5.Environment requirement:

    ?Conditions: Indoors, free from direct sunlight, corrosive gases, flammable gases, oil mist, water vapor, metal particles, etc.

    ?Altitude: 0~2,000m. Derating is required above 1,000m, Rated output current should be derated 1% per 100m increase above 1000m.

    ?Ambient temperature: -10°C~50°C.Derating 1% per centigrade additional for temperature >50°C

    ?Vibration: Less than 5.9 m/s² (0.6g)

    ?Storage temperature: -40~70°C

    ?Protection grade: IP20

    ?Type of cooling: Air cooling

    6.Applications:

    Fan, oil pump, water pump, compressor, air compressor, injection molding machine, engraving machine, textile, packaging, conveyor, treadmill, printing machine, lathe, machine tool, hydraulic machine, wire drawing, winder/un-winder, knitting Machine, compressor, extruding machine, injection machine, AC motor, braiding machine, pressure fan, forced draught blower, blower, blowing machine, blow molding machine, root's blower, film blowing machine, cutter bar, cut-off machine, slitter, Cutting machine, grinder, cluster, glazing machine, polisher, polishing machine, laundry-drier, drying machine, ball crusher, ball grinding mill, drawing machine.

    7.Key words

    Frequency inverters, AC Drives, variable frequency drives (VFD), AC motor drives, frequency converters, frequency changers, adjustable speed drives (ASD), adjustable frequency drives (AFD), variable speed drives (VSD), AC motor speed controller, AC variable frequency drive, variable frequency inverter, AC motor speed controller, EMI filter, Input EMI Filters, Output EMI Filters, AC Choke, AC Reactor, Input AC Choke, Output AC Choke, Input AC Reactor, Output AC Reactor, DC Choke, DC Reactor, Input DC Choke, Output DC Reactor, Input DC Reactor, Servo Drive, Servo Motor & Drive, Servo Motor & Drive System


Send your message to this supplier
To:  

Jiangsu Gtake Electric Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>